MEDPROSHOP
Brewer Access 5000—Manual
New Upholstery
Ready to ship
(Please call for More Information)
Brewer Access 5000—Manual
New Upholstery
Ready to ship
(Please call for More Information)
Burdick Eclipse 850 EKG Machine
High performance and unequaled reliability in a compact package
Proven in over 10,000 installations, the Burdick Eclipse 850 EKG Machine delivers high performance in a compact package. With all the functionality of a hospital-grade ECG, it is the ideal choice for medical professionals in either a hospital or physician’s office, where ECGs are performed frequently
Burdick Eclipse 850 EKG Machine Technical Specifications:
Dimensions 11.75″ x 18.16″ x 4.14″ (299 x 462 x 105 mm)
Weight 14.2 lbs (6.45 Kg)
Display Backlit 320 x 240 LCD
Keyboard Full alphanumeric keypad
Input/output Compact flash (proprietary true IDE); Units w/communications Serial RS-232; Telephone line interface (RJ11C); Analog/TTL/ExTOL output (25 pin D)
Data storage 40 patient records
Power requirements AC operation: 115/230 V AC +/-10%, 0.80/0.40 A, 50/60 Hz; Fuses: For 115 V, 1.0A, 250 V type T; for 230 V, 0.5A 250 V type T; Battery operation: 16.8V NiCad rechargeable battery pack (80 minutes w/o printing or 40 minutes w/ 40 ECGs)
Printout Printout device: 216 mm thermal dot array; Paper dimensions: 8.5″ x 11″ (US letter) or 210 mm x 300 mm (A4); Paper type: Thermal sensitive; Chart
speeds: 10, 25, 50 mm/sec; Gain: 5, 10, 20 mm/mV; 10 mm/mV limb with 5 mm/mV chest; 20 mm/mV limb with 10 mm/mV chest; Printout formats:
Standard or cabrera 3, 4, 6 or 12 channel; additional rhythm formats
Acquisition Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, V4R; supports Frank X, Y, Z, Cabrera, and Nehb D, A, J; Interpretation (option): Diagnosis, measurements, reason statements; Modes: Automatic, rhythm or manual; Frequency response: Meets or exceeds ANSI/AAMI EC11-1991 standard; Input impedance: Meets or exceeds ANSI/AAMI EC11-1991 standard; Electrode offset tolerance: +/-300 mV; A/D conversion: 10 µV LSB; Artifact filter response:
40 Hz, -3db; Data resolution: 500 samples/second, 5 µV
Environmental Operating temperature: 50°F to 104°F (10°C to 40°C); Operating relative specifications humidity: 25% to 95%, non-condensing; Operating atmospheric pressure: 700 KPa to 1060 KPa; Storage temperature: -4°F to 131°F (-20°C to 55°C); Storage relative humidity: 25% to 95%, non-condensing; Storage atmospheric pressure: 700 KPa to 1060 KPa
Conforms to standards EN60601-1:1999 / CSA C22.2 no. 601-1-M90 UL2601-1 EN60601-2-25 / CSA C22.2 no. 601-2-25 EN60601-1-2:1993
Safety Leakage current: Patient <10 µA, chassis <100 µA; Defibrillation protection: to 5000 V, 400J
Burdick Eclipse 850 EKG Machine
High performance and unequaled reliability in a compact package
Proven in over 10,000 installations, the Burdick Eclipse 850 EKG Machine delivers high performance in a compact package. With all the functionality of a hospital-grade ECG, it is the ideal choice for medical professionals in either a hospital or physician’s office, where ECGs are performed frequently
Burdick Eclipse 850 EKG Machine Technical Specifications:
Dimensions 11.75″ x 18.16″ x 4.14″ (299 x 462 x 105 mm)
Weight 14.2 lbs (6.45 Kg)
Display Backlit 320 x 240 LCD
Keyboard Full alphanumeric keypad
Input/output Compact flash (proprietary true IDE); Units w/communications Serial RS-232; Telephone line interface (RJ11C); Analog/TTL/ExTOL output (25 pin D)
Data storage 40 patient records
Power requirements AC operation: 115/230 V AC +/-10%, 0.80/0.40 A, 50/60 Hz; Fuses: For 115 V, 1.0A, 250 V type T; for 230 V, 0.5A 250 V type T; Battery operation: 16.8V NiCad rechargeable battery pack (80 minutes w/o printing or 40 minutes w/ 40 ECGs)
Printout Printout device: 216 mm thermal dot array; Paper dimensions: 8.5″ x 11″ (US letter) or 210 mm x 300 mm (A4); Paper type: Thermal sensitive; Chart
speeds: 10, 25, 50 mm/sec; Gain: 5, 10, 20 mm/mV; 10 mm/mV limb with 5 mm/mV chest; 20 mm/mV limb with 10 mm/mV chest; Printout formats:
Standard or cabrera 3, 4, 6 or 12 channel; additional rhythm formats
Acquisition Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, V4R; supports Frank X, Y, Z, Cabrera, and Nehb D, A, J; Interpretation (option): Diagnosis, measurements, reason statements; Modes: Automatic, rhythm or manual; Frequency response: Meets or exceeds ANSI/AAMI EC11-1991 standard; Input impedance: Meets or exceeds ANSI/AAMI EC11-1991 standard; Electrode offset tolerance: +/-300 mV; A/D conversion: 10 µV LSB; Artifact filter response:
40 Hz, -3db; Data resolution: 500 samples/second, 5 µV
Environmental Operating temperature: 50°F to 104°F (10°C to 40°C); Operating relative specifications humidity: 25% to 95%, non-condensing; Operating atmospheric pressure: 700 KPa to 1060 KPa; Storage temperature: -4°F to 131°F (-20°C to 55°C); Storage relative humidity: 25% to 95%, non-condensing; Storage atmospheric pressure: 700 KPa to 1060 KPa
Conforms to standards EN60601-1:1999 / CSA C22.2 no. 601-1-M90 UL2601-1 EN60601-2-25 / CSA C22.2 no. 601-2-25 EN60601-1-2:1993
Safety Leakage current: Patient <10 µA, chassis <100 µA; Defibrillation protection: to 5000 V, 400J
Cadwell Sierra Summit EMG/NCV/EP system, 2 channels Win 10 Laptop,
Comes with 2 Ch Amplifier
EStim
Power cord
Dell laptop computer
Sierra summit base
Cadwell Sierra Summit EMG/NCV/EP system, 2 channels Win 10 Laptop,
Comes with 2 Ch Amplifier
EStim
Power cord
Dell laptop computer
Sierra summit base
ECG100G single channel electrocardiograph can print ECG waveform with thermal printing system, prompt for “Lead off” and “Lack of paper”, display multi-language interface, record ECG waveform with manual or auto-mode, which is very convenient for operation.
Unit is in working condition.
A power cord is included.
Paper is included.
ECG clips are included.
Product is sold as seen on photo. Please view photos.
Please give us a call for any of your inquiries.
ECG100G single channel electrocardiograph can print ECG waveform with thermal printing system, prompt for “Lead off” and “Lack of paper”, display multi-language interface, record ECG waveform with manual or auto-mode, which is very convenient for operation.
Unit is in working condition.
A power cord is included.
Paper is included.
ECG clips are included.
Product is sold as seen on photo. Please view photos.
Please give us a call for any of your inquiries.
MEDPROSHOP
We Buy & Sell all types of Medical Equipment
*Any Returns need to be Authorized by Seller with and RMA #
Or you will not get a Credit for your Return.
Buyer Pays for any and all returns to Seller.
Buyer has a 30 Day warranty on Equipment purchased.
After 30 Days NO RETURNS ACCEPTED AT ALL
If Item is damaged when received Buyer must contact Seller
Within 24 hours to report a claim on the Shipping compan
MEDPROSHOP
We Buy & Sell all types of Medical Equipment
*Any Returns need to be Authorized by Seller with and RMA #
Or you will not get a Credit for your Return.
Buyer Pays for any and all returns to Seller.
Buyer has a 30 Day warranty on Equipment purchased.
After 30 Days NO RETURNS ACCEPTED AT ALL
If Item is damaged when received Buyer must contact Seller
Within 24 hours to report a claim on the Shipping compan
070-044 Crile Hemostatic Forceps, Curved, 14 cm
If you require further information, please feel free to call us at: (954) 482 2061
070-044 Crile Hemostatic Forceps, Curved, 14 cm
If you require further information, please feel free to call us at: (954) 482 2061
070-042 Crile Hemostatic Forceps, Straight, 14 cm
If you require further information, please feel free to call us at: (954) 482 2061
070-042 Crile Hemostatic Forceps, Straight, 14 cm
If you require further information, please feel free to call us at: (954) 482 2061
Cryomedics Inc. KRMED Mt 600 Cryo Gun.
SN- OKEF 71
Cryomedics Inc. KRMED Mt 600 Cryo Gun.
SN- OKEF 71
Costmetic Laser and comes with 2 Hand Pieces
MaxG Jan 2023
MaxYs Feb 2022
Costmetic Laser and comes with 2 Hand Pieces
MaxG Jan 2023
MaxYs Feb 2022